TC-48 Series Preset Timer/Counter
Multi-function 6 digit Timer/Counter with RS-232, RS-485, RS-422 Serial Communications
This Fargo Controls Inc. is proud to announce its latest addition, the TC series. This series is a powerful 6-digit multifunction programmable preset Timer/Counter with a communication interface. It has RS-232, RS-485, RS-422 Serial Communications and supports Modbus protocol. This series can be connected to a PC for programming and logging of data.
The Timer has 10 output modes, 10 timing ranges in 3 configurations.
The Counter has 12 output and 5 input modes in 6 configurations and scaling for displaying of specific units or lengths.
The Tachometer displays rate per second (Hz) and has 4 output modes.
|
Call 732-389-3376 for complete information or to speak with an application engineer
General Specifications |
Model |
TC-Pro482CRA (panel mount)
TC-Pro482CRA-D (DIN rail mount) |
TC-Pro482CRD (panel mount)
TC-Pro482CRD-D (DIN rail mount) |
Function |
Digital timer/counter/tachometer |
Supply voltage |
100-240VAC (50/60Hz) ±10%, |
16-24VDC ±10% (permissible ripple:20% (p-p) max.) |
Power consumption |
Approx. 6.2VA at 264VAC, Approx. 5.1VA at 26.4VAC, Approx. 2.4W at 24VDC |
Mounting method |
Panel mounting (45 x 45mm cutout) |
External connections |
Screw terminals, tightening torque 0.5 N•m Max. |
Display |
6 Digit 7-segment, LCD display, Present value: 9-mm-high characters, white, Set value: 4-mm-high characters, white |
Input method |
NPN No-voltage input/voltage input (switchable)
No-voltage input
ON impedance: 1kΩ max. (leakage current: 5-20 mA at 0Ω) ON residual voltage: 3V max. OFF impedance: 100kΩ min.
PNP Voltage Input High (logic) level: 4.5 to 30 VDC Low (logic) level: 0 to 2 VDC (Input resistance: approx. 4.7 kΩ |
Output method |
Relay, (optional transistor output) |
Output |
2 SPST NO contact output: 5A at 250 VAC, resistive load (cosФ=1)
Minimum applied load: 10 mA at 5 VDC (failure level: P, reference value)
Transistor output: NPN open collector, max. 100mA at 30 VDC
Residual voltage: 1.5 VDC max. (approx. 1V)
Output category according to EN60947-5-1 for timers with Contact outputs
(AC-15; 250V 3A / AC-13; 250V 5A / DC-13; 30V 0.5A)
Output category according to EN60947-5-2 for timers with Transistor outputs
(DC-13; 30V 100 mA)NEMA B300 Pilot Duty, 1/4 HP 5-A resistive load at 120 VAC, 1/3 HP 5-A resistive load at 240 VAC |
One-shot output time |
0000.01-9999.99s |
External power supply |
12VDC (15%), 80mA |
Keypad lockout |
Yes, 5 key protection modes |
Sensor waiting time |
250 ms max. (control output is turned OFF and no input is accepted during sensor waiting time) |
Memory backup |
EEPROM (overwrites: 100,000 times min.) that can store data for 10 years min. |
Ambient temperature |
Operating: -10 to 55°C (with no icing or condensation) Storage: -25 to 65°C (with no icing or condensation) |
Ambient humidity |
25% to 85% |
Case |
Black plastic |
Attachments |
Waterproof gasket, flush mounting adapter |
Life expectancy |
Mechanical: 10,000,000 operations min.
Electrical: 100,000 operations min. (5 A at 250 VAC, resistance load) |
EMC |
(EMI)
Emission Enclosure:
Emission AC mains:
(EMS)
Immunity ESD:
Immunity RF-interference:
Immunity Conducted Disturbance:
Immunity Burst:
Immunity Surge:
Immunity voltage Dip/interruption: |
EN61326
EN55011
EN55011
EN61326
EN61000-4-2
EN61000-4-3
EN61000-4-6
EN61000-4-4
EN61000-4-5
EN61000-4-11 |
Weight Approx. |
168g |
|
Timer Specifications |
Functions |
Timer, Twin Timer or 2-Stage Timer |
Time range |
99.999s (0.001-s unit), 9999.99s (0.01-s unit), 99999.9s (0.1-s unit)999999s (1-s unit), 9999min59s (1-s unit), 99999.9min (0.1-min unit),999999min (1-min unit), 9999h59min (1-min unit), 99999.9h (0.1-h unit), 999999h (1-h unit) |
Timer mode |
Elapsed time (UP), Remaining time (down) (selectable) |
Input signals |
Signal, reset, gate |
Signal, Reset, Gate |
Minimum input signal width: 1 or 20 ms (selectable, same setting for all inputs) |
Power reset |
Minimum power-opening time: 0.5 s (exceptA-3, b-1 and F mode) |
Reset system |
Power reset (execptA-3, b-1and F mode), external and manual reset |
Output modes |
A, A-1, A-2, A-3, b, b-1, d, E, F, Z, ton or toff |
Counter Specifications |
Function |
1-stage counter, 2-stage counter, total counter, batch counter, dual counter, and tachometer (selectable) |
Digits |
6 digits, PV/SV (-99,999~999,999) |
Input signal |
CP1, CP2, reset1, and reset 2 |
Max. counting speed |
30 Hz or 5kHz (selectable, ON/OFF ratio 1:1), common setting for CP1 and CP2 |
Input mode |
Increment, decrement, command, individual, and quadrature |
Reset input |
Minimum input signal width: 1/20 ms (selectable, same setting for all inputs) |
Reset system |
External, manual, and automatic reset (internal according to C,R,P and Q mode operation) |
Output modes |
N,F,C,R,K-1,P,Q,A,K-2,D,L,H |
Prescaling function |
Yes (000.001~999.999) multiplier |
Decimal point |
Yes (rightmost 3 digits) |
Tachometer Specifications |
Function |
Tachometer (Hz) |
Digits |
6 digits |
Input signal |
CP1, reset1, and reset 2 |
Max. counting speed |
30 Hz or 5kHz (selectable, ON/OFF ratio 1:1), common setting for CP1 and CP2 |
Reset input |
Minimum input signal width: 1/20 ms (selectable, same setting for all inputs) |
Reset system |
External, manual (Holds the displayed value and outputs) |
Output modes |
High-Low, Area, High-high, Low-Low |
Average processing |
none, average of 2,4 or 8 measurements |
Auto zero |
Programmable 00.01 - 99.99s |
Startup time |
Programmable 00.00 - 99.99s |
Decimal point |
Yes (rightmost 3 digits) |
Wiring |
Accessories |
Wiring for Din Rail Version
|
Model |
Description |
CAB-090A232 |
9-pin Female D-sub cable for RS-232 connector, 1.5m Cable |
CAB-090A485 |
9-pin Female D-sub cable for RS-485 connector, 1.5m Cable |
CAB-090A422 |
9-pin Female D-sub cable for RS-422 connector, 1.5m Cable |
|
ADP-090401 |
9-pin male D-sub adapter for CAB-090A232/CAB-090A485/CAB-090A422 |
|
|