Proximity Sensors
     Operating Principles
     Inductive
     Capacitive
     Magnetic
     Photoelectric
     Connector Cord Sets
     Value Line Proximity
     Sensors

Counters

     Totalizing
     Preset
     Length Measuring
     Mechanical
     Multifunction

Timers

Timers
     Hour Meters
     Elapse Time
     Preset
     Multifunction

Controls
     Sensor Power Supplies
     Timing Controls
     Rotation Controls

 

Battery powered LCD electronic counter special
Battery powered LCD counter at a great price. $34.95 each

High operating temperature inductive sensors
High operating temperature inductive sensors
120°C / 248°F


TC-48 Series Preset Timer/Counter
Multi-function 6 digit Timer/Counter with RS-232, RS-485, RS-422 Serial Communications

This Fargo Controls Inc. is proud to announce its latest addition, the TC series. This series is a powerful 6-digit multifunction programmable preset Timer/Counter with a communication interface. It has RS-232, RS-485, RS-422 Serial Communications and supports Modbus protocol. This series can be connected to a PC for programming and logging of data.

The Timer has 10 output modes, 10 timing ranges in 3 configurations.

The Counter has 12 output and 5 input modes in 6 configurations and scaling for displaying of specific units or lengths.

The Tachometer displays rate per second (Hz) and has 4 output modes.


Features  

Highly visible backlit LCD display
Visual alerts when output status changes
 2 output relays
 PNP/NPN selectable DC-voltage inputs
 Up/down, add/subtract and quadrature inputs



 12VDC supply for powering sensor and encoders
 Keypad lock out functions
 Communications for connecting to PC/HMI
 Free Software to connect to a PC
 Low cost

 Panel or DIN
Rail mount versions

Preset Counter, Timer
DIN Rail Mount Preset Counter, Timer

Call 732-389-3376 for complete information or to speak with an application engineer


General Specifications
Model TC-Pro482CRA (panel mount)
TC-Pro482CRA-D (DIN rail mount)
TC-Pro482CRD (panel mount)
TC-Pro482CRD-D (DIN rail mount)
Function Digital timer/counter/tachometer
Supply voltage 100-240VAC (50/60Hz) ±10%, 16-24VDC ±10% (permissible ripple:20% (p-p) max.)
Power consumption Approx. 6.2VA at 264VAC, Approx. 5.1VA at 26.4VAC, Approx. 2.4W at 24VDC
Mounting method Panel mounting (45 x 45mm cutout)
External connections Screw terminals, tightening torque 0.5 N•m Max.
Display 6 Digit 7-segment, LCD display, Present value: 9-mm-high characters, white, Set value: 4-mm-high characters, white
Input method NPN No-voltage input/voltage input (switchable) No-voltage input ON impedance: 1kΩ max. (leakage current: 5-20 mA at 0Ω) ON residual voltage: 3V max. OFF impedance: 100kΩ min.
PNP Voltage Input High (logic) level: 4.5 to 30 VDC Low (logic) level: 0 to 2 VDC (Input resistance: approx. 4.7 kΩ
Output method Relay, (optional transistor output)
Output 2 SPST NO contact output: 5A at 250 VAC, resistive load (cosФ=1)
Minimum applied load: 10 mA at 5 VDC (failure level: P, reference value)
Transistor output: NPN open collector, max. 100mA at 30 VDC
Residual voltage: 1.5 VDC max. (approx. 1V)
Output category according to EN60947-5-1 for timers with Contact outputs
(AC-15; 250V 3A / AC-13; 250V 5A / DC-13; 30V 0.5A)
Output category according to EN60947-5-2 for timers with Transistor outputs
(DC-13; 30V 100 mA)NEMA B300 Pilot Duty, 1/4 HP 5-A resistive load at 120 VAC, 1/3 HP 5-A resistive load at 240 VAC
One-shot output time 0000.01-9999.99s
External power supply 12VDC (15%), 80mA
Keypad lockout Yes, 5 key protection modes
Sensor waiting time 250 ms max. (control output is turned OFF and no input is accepted during sensor waiting time)
Memory backup EEPROM (overwrites: 100,000 times min.) that can store data for 10 years min.
Ambient temperature Operating: -10 to 55°C (with no icing or condensation) Storage: -25 to 65°C (with no icing or condensation)
Ambient humidity

25% to 85%

Case Black plastic
Attachments Waterproof gasket, flush mounting adapter
Life expectancy Mechanical: 10,000,000 operations min.
Electrical: 100,000 operations min. (5 A at 250 VAC, resistance load)
EMC (EMI)
Emission Enclosure:
Emission AC mains:
(EMS)
Immunity ESD:
Immunity RF-interference:
Immunity Conducted Disturbance:
Immunity Burst:
Immunity Surge:
Immunity voltage Dip/interruption:
EN61326
EN55011
EN55011
EN61326
EN61000-4-2
EN61000-4-3
EN61000-4-6
EN61000-4-4
EN61000-4-5
EN61000-4-11
Weight Approx. 168g


Timer Specifications
Functions Timer, Twin Timer or 2-Stage Timer
Time range 99.999s (0.001-s unit), 9999.99s (0.01-s unit), 99999.9s (0.1-s unit)999999s (1-s unit), 9999min59s (1-s unit), 99999.9min (0.1-min unit),999999min (1-min unit), 9999h59min (1-min unit), 99999.9h (0.1-h unit), 999999h (1-h unit)
Timer mode Elapsed time (UP), Remaining time (down) (selectable)
Input signals Signal, reset, gate
Signal, Reset, Gate Minimum input signal width: 1 or 20 ms (selectable, same setting for all inputs)
Power reset Minimum power-opening time: 0.5 s (exceptA-3, b-1 and F mode)
Reset system Power reset (execptA-3, b-1and F mode), external and manual reset
Output modes A, A-1, A-2, A-3, b, b-1, d, E, F, Z, ton or toff

Counter Specifications
Function 1-stage counter, 2-stage counter, total counter, batch counter, dual counter, and tachometer (selectable)
Digits 6 digits, PV/SV (-99,999~999,999)
Input signal CP1, CP2, reset1, and reset 2
Max. counting speed 30 Hz or 5kHz (selectable, ON/OFF ratio 1:1), common setting for CP1 and CP2
Input mode Increment, decrement, command, individual, and quadrature
Reset input Minimum input signal width: 1/20 ms (selectable, same setting for all inputs)
Reset system External, manual, and automatic reset (internal according to C,R,P and Q mode operation)
Output modes N,F,C,R,K-1,P,Q,A,K-2,D,L,H
Prescaling function Yes (000.001~999.999) multiplier
Decimal point Yes (rightmost 3 digits)

Tachometer Specifications
Function Tachometer (Hz)
Digits 6 digits
Input signal CP1, reset1, and reset 2
Max. counting speed 30 Hz or 5kHz (selectable, ON/OFF ratio 1:1), common setting for CP1 and CP2
Reset input Minimum input signal width: 1/20 ms (selectable, same setting for all inputs)
Reset system External, manual (Holds the displayed value and outputs)
Output modes High-Low, Area, High-high, Low-Low
Average processing none, average of 2,4 or 8 measurements
Auto zero Programmable 00.01 - 99.99s
Startup time Programmable 00.00 - 99.99s
Decimal point Yes (rightmost 3 digits)


Wiring Accessories

Wiring

Wiring for Din Rail Version
Wiring

cable
Model Description
CAB-090A232 9-pin Female D-sub cable for RS-232 connector, 1.5m Cable
CAB-090A485 9-pin Female D-sub cable for RS-485 connector, 1.5m Cable
CAB-090A422 9-pin Female D-sub cable for RS-422 connector, 1.5m Cable
adaptor
ADP-090401 9-pin male D-sub adapter for CAB-090A232/CAB-090A485/CAB-090A422

Preset Counter,Timer dimensions

 

 




 
 
Home            Specials            News            About Us            Literature Request            Contact Us
Copyright © 1998-2020 Fargo Controls Inc. All Rights Reserved.